Application:

The equipment can heat well fluids coming from choke manifold to prevent freezing/waxing of crude.

Can heat Raw Natural Gas before turbines, Sulfur Gas in sulfur processing facilities, and maintain proper temperature to meet process requirements.

 

Product Advantage:

Can customized made for Sour Medium, Heavy Fouling Medium, Salty Medium; Various style of burner and fuel as per client requirements; Specified PLC for automatic remote control; Skid-mounted or trailer-mounted.

 

 

Detail Description:

 

Insulation: Aluminum silicate fiber board insulation with stainless steel board packaging, to ensure a beautiful looking, and efficient heating operation, thermal efficiency up to 80%.

 

Combustion Chamber: Its designed according to the flame geometry, and considering the structure diagram of the burner and the size of the combustion chamber match, at the same time in order to prevent the damage of deflagration to the heating furnace, the furnace end is equipped with explosion-proof door.

 

PLC Auto Controller ensure the overall operation is simple and smooth, low water used, low equipment failure rate:

* The output load is automatically adjusted according to the medium temperature or water bath temperature required by the process.

* Indicate Water Level, Water Temperature, Medium Temperature, Combustion State, etc.

* Automatically adjusts the output power of furnace, detects the safety interlock condition of the system to achieve the unattended function.

* The burner control system adopts PLC control, which controls medium temperature within 2 ; The burner adopts automatic proportional adjustment burner, when the gas supply pressure is stable, the combustion effect is very good.

* Automatic ignition, Flame monitoring, Flame off protection function: (electromagnetic valve and flame monitoring interlock); Gas automatic leak control.

* High/low gas pressure, low combustion air pressure, flameout, cheat detection fault, etc.

Heating Power

Upto 4200 kw

Working Medium

Crude Oil

Inlet Pressure (Max./Min.psig)

2000/500

Tube Outside Diameter

4” or as per request

Material of Construction

ASTM A106B or as per request

Wall Thickness

Sch40 or as per request

Design Temperature  °F (°C)

212 (100)

Design Pressure psig (barg)

2000 (138)

Medium Pass/Coil Qty

 Single/Double Pass